Read e-book online affinity chromatography principles and methods PDF

By GE HEalthcare

Show description

Read Online or Download affinity chromatography principles and methods PDF

Best chemistry books

Graph Theory and Topology in Chemistry - download pdf or read online

Members from ten diversified nations attended the convention which was once in lots of methods a sequel to a symposium held on the collage of Georgia in April 1983. The central target of this convention used to be to supply a discussion board for chemists and mathematicians to engage and turn into larger trained on present actions and new advancements within the large parts of chemical topology and chemical graph idea.

Extra info for affinity chromatography principles and methods

Sample text

Immediately re-equilibrate with 5–10 column volumes of binding buffer. 0 per ml fraction), so that the final pH of the fractions will be approximately neutral. 35 Table 3 gives examples of some typical binding and elution conditions that have been used with Protein A Sepharose. Table 3. 0 3–4 (using thiocyanate) Binding strengths are tested with free protein A. They can be used as a guide to predict the binding behaviour to a protein A affinity medium. However, when coupled to an affinity matrix the interaction may be altered.

Media characteristics Ligand and density pH stability* HiTrap IgY Purification HP 2-mercaptopyridine 3 mg/ml Long term 3–11 Short term 2–13 Mean particle size 34 µm * Long term refers to the pH interval over which the medium is stable over a long period of time without adverse effects on its subsequent chromatographic performance. Short term refers to the pH interval for regeneration, cleaning-in-place and sanitization procedures. Storage Wash the column with 5 column volumes 20% ethanol and store at +4 to +8 °C.

HiTrap Chelating HP columns (1 ml or 5 ml) can be used with a syringe, a peristaltic pump or a chromatography system. For even larger capacity, pack Chelating Sepharose Fast Flow into a suitable column (see Appendix 3). The loss of metal ions is more pronounced at lower pH. e. all metal ions removed) between each purification if the same protein is going to be purified. e. replace metal ions) the column after 5–10 purifications. Reuse of purification columns depends on the nature of the sample and should only be considered when processing identical samples to avoid cross contamination.

Download PDF sample

affinity chromatography principles and methods by GE HEalthcare


by Joseph
4.4

Rated 4.86 of 5 – based on 26 votes